Fuse Failure Relays

Fuse failure relays are commonly used in critical applications where the failure of a fuse can have severe consequences, such as in industrial plants, power distribution systems, and electrical panels. They help ensure the continuity and reliability of electrical systems by providing timely detection and notification of fuse failures, allowing for prompt troubleshooting and corrective actions. Fuses can fail due to various reasons, such as prolonged overcurrent, excessive temperature, or manufacturing defects. The Fuse Failure Relays are installed in conjunction with fuses to monitor their status and provide an indication and trigger an alarm when a fuse fails. The instrument provides LED indications of each fuse status on the front panel and also provides one potential free Relay contact for alarm purposes.

Fuse Failure Relay

https://www.ashecontrols.com/wp-content/uploads/2023/12/Fuse-Failure-Relay-Diagram-01.jpg
Features :
Fuse monitoring and Alarm.
LEDs for fuse status indications.
Control Relay output for Fuse blown condition.
Very low power consumption and heat dissipation.
Rugged, industrial grade ABS enclosure.
High Noise immunity.
Flush-panel / DIN Rail mounting.

Product Models

https://www.ashecontrols.com/wp-content/uploads/2023/08/FF6.jpg

Why you should buy:

Continuous Fuse monitoring
LED indication to indicate fault
Relay changeover contact.

Fuse Failure Relay- 6 Channel

FFR-6

Input 0 to 230 V AC.
Six Fuses monitored.
Six LEDs to indicate status of Fuses.
Single Relay changeover contacts for Fuse fault.
Contact Rating of 10 Ampere @ 230 V AC.
Power Supply 230 V AC, 50 Hz.
Bezel dimensions 96 x 96 mm.
Front panel mounting execution.
Flush-panel / DIN Rail mounting
https://www.ashecontrols.com/wp-content/uploads/2023/08/FFR8.jpg

Why you should buy:

Continuous Fuse monitoring
LED indication to indicate fault
Relay changeover contact.

Fuse Failure Relay- 8 Channel

FFR-8

Input 0 to 230 V AC.
Eight Fuses monitored.
Eight LEDs to indicate status of Fuses.
Single Relay changeover contacts for Fuse fault.
Contact Rating of 10 Ampere @ 230 V AC.
Power Supply 230 V AC, 50 Hz.
Bezel dimensions 96 x 96 mm.
Front panel mounting execution.
https://www.ashecontrols.com/wp-content/uploads/2023/08/FFR10.jpg

Why you should buy:

Continuous Fuse monitoring
LED indication to indicate fault
Relay changeover contact.

Fuse Failure Relay-10 Channel

MFR-10

Input 0 to 230 V AC.
Ten Fuses monitored.
Ten LEDs to indicate status of Fuses.
Dual Relay changeover contacts for Fuse fault.
Contact Rating of 10 Ampere @ 230 V AC.
Power Supply 230 V AC, 50 Hz.
Dimensions 110x75x100 mm.
DIN Rail mount execution.
Extension Resistor Board for high current dropping.